Protect-All is a orthophosphate liquid blend formulated specifically to be used for the inhibition of internal corrosion in potable water distribution systems.  Protect-All liquid contains cleansing ingredients necessary for the gradual removal of existing mineral scale deposits.  The product includes metal phosphatizing ingredients required for the development and maintenance of corrosion protective film formation.  Consider Protect-All liquid potable water treatment if you are in need of an effective corrosion inhibitor.

  • sample11_sub_icon_roll  Protect-All is a unique orthophosphate liquid blend for the control of internal corrosion in potable and non-potable water distribution systems.

  • sample11_sub_icon_roll   Protect-All will suppress primarily the anodic electrochemical potential thereby neutralizing the circuit necessary to form a corrosion cell on the interior surface of the distribution pipe and equipment.

  • sample11_sub_icon_roll   Along with functioning as a corrosion inhibitor, Protect-All has ingredients that will stabilize mineral ions such as iron, calcium, magnesium and manganese preventing mineral scale deposits and discolored water complaints.

  • sample11_sub_icon_roll  Once added to a water distribution system, the treatment is also an excellent pH buffering agent to prevent swings in pH to the acidity side.

  • sample11_sub_icon_roll  Reduces the demand for chlorine/chlorimines because of the stabilization of minerals and reduction of scale deposits - effectively improving disinfection throughout the water distribution system.

  • sample11_sub_icon_roll  Gradual removal and inhibition of mineral scale deposits formations in hot water lines and residential water heaters.
Product_Data_box41

   redball bullet02   Composition: .............................................................................. Liquid  .......................................  Liquid
   redball bullet03   Appearance: ..................................................................... Clean, Clear  ........................... Clean, Clear
   redball bullet04   Bulk Density: .................................................................... 11.25 lbs/gal  .............................  9.84 lbs/gal
   redball bullet05   pH of 1% solution:  ................................................................. 5.1 - 5.4  ................................... 5.6 - 5.9
   redball bullet06    % PO4:  ............................................................................................... 36  .............................................. 20

   redball bullet09   Specific Gravity:  ............................................................................ 1.36  ......................................... 1.18
   redball bullet10   NSF Standard 60 Certified: ..................................... yes (since 1991)  .................... yes (since 1991)
   redball bullet11   NSF max. Potable dosage: ................................ 30 mg/L (by weight)  ............... 45 mg/L (by weight)   

Product_Data_box42

Protect-All blended liquid phosphate can be applied to a water system directly from the container and into the water system by use of a chemical injection metering pump.  We do not recommend dilution of either concentration.  Typical potable water treatment dosages range from 0.75 to 3.75 mg/L (calculated) and higher for non-potable systems.

Product_Data_box43

Protect-All liquid is packaged in 5, 30, and 55 gallon containers FOB Clearwater, FL 33760.  Protect-All is shipped securely sealed in our containers.  Please refer to our Material Safety Data Sheet for handling information:  Material Safety Data Sheet

Liquid packaging cluster0202
SportsLine03

                                                                                                                 NOTICE
The information herein is to our knowledge true and accurate.  All information appearing on this document is based on data obtained from the manufacturer and/or recognized technical sources.  Because of conditions beyond our control, we make no warranty or representation, expressed or implied, except that the product discussed herein conform to the chemical descriptions shown on their labels/product data.   Information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use.  In no event will SPER Chemical Corporation be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information or the product to which the information refers.  No agent, representative or employee of this company is authorized to vary any of the terms of this notice.